{"id":8766,"date":"2023-09-25T10:29:22","date_gmt":"2023-09-25T17:29:22","guid":{"rendered":"https:\/\/www.alconlighting.com\/blog\/?p=8766"},"modified":"2024-02-23T13:42:03","modified_gmt":"2024-02-23T20:42:03","slug":"tm-30-20-color-rendering-lighting-design","status":"publish","type":"post","link":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/","title":{"rendered":"Reimagining Color Rendering in Lighting Design: An Introduction to TM-30-20"},"content":{"rendered":"\n<p>When it comes to lighting design, color rendering can greatly impact the overall aesthetic and functionality of a space. The ability of a light source to accurately reveal the colors of objects it lights is essential, whether it&#8217;s for retail displays, museum exhibits or residential homes.&nbsp;<\/p>\n\n\n\n<p>Traditionally, the <a href=\"https:\/\/www.alconlighting.com\/blog\/lighting-design\/color-rendering-index-cri\/\">Color Rendering Index (CRI)<\/a> has been used as the standard for measuring color rendering accuracy. However, with the emergence of new lighting technologies, such as LEDs, demand for a more comprehensive and accurate evaluation method arose. This led to the development of ANSI\/IES TM-30-20, a revolutionary approach to assessing color rendition in lighting.<\/p>\n\n\n\n<div class=\"wp-block-yoast-seo-table-of-contents yoast-table-of-contents\"><h2>Table of Contents<\/h2><ul><li><a href=\"#h-understanding-cri-and-its-limitations\" data-level=\"2\">Understanding CRI and Its Limitations<\/a><\/li><li><a href=\"#h-the-rise-of-tm-30-15-a-more-comprehensive-approach\" data-level=\"2\">The Rise of TM-30-15: A More Comprehensive Approach<\/a><ul><li><a href=\"#h-color-fidelity-index-rf\" data-level=\"3\">Color Fidelity Index (Rf)<\/a><\/li><li><a href=\"#h-gamut-index-rg\" data-level=\"3\">Gamut Index (Rg)<\/a><\/li><li><a href=\"#h-color-vector-graphics\" data-level=\"3\">Color Vector Graphics<\/a><\/li><\/ul><\/li><li><a href=\"#h-the-advancements-of-tm-30-20-a-further-refinement\" data-level=\"2\">The Advancements of TM-30-20: A Further Refinement<\/a><\/li><li><a href=\"#h-visualizing-color-rendering-with-tm-30-20\" data-level=\"2\">Visualizing Color Rendering with TM-30-20<\/a><\/li><li><a href=\"#h-utilizing-tm-30-20-in-lighting-design\" data-level=\"2\">Utilizing TM-30-20 in Lighting Design<\/a><ul><li><a href=\"#h-1-specifying-color-rendering-requirements\" data-level=\"3\">1. Specifying Color Rendering Requirements<\/a><\/li><li><a href=\"#h-2-understanding-priority-levels\" data-level=\"3\">2. Understanding Priority Levels<\/a><\/li><li><a href=\"#h-3-evaluating-light-sources\" data-level=\"3\">3. Evaluating Light Sources<\/a><\/li><li><a href=\"#h-4-collaborating-with-manufacturers\" data-level=\"3\">4. Collaborating with Manufacturers<\/a><\/li><\/ul><\/li><li><a href=\"#h-conclusion\" data-level=\"2\">Conclusion<\/a><\/li><\/ul><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-understanding-cri-and-its-limitations\">Understanding CRI and Its Limitations<\/h2>\n\n\n\n<p>The Color Rendering Index (CRI) was developed in the 1970s based on the 1931 technique of colorimetry.<sup>[1]<\/sup> Color rendering refers to the ability of a light source to accurately represent the colors of objects as they would appear under a reference light source, sunlight, incandescent, fluorescent, halogen or LED lamps.&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"500\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png\" alt=\"Color Rendering Index (CRI) infographic showing color rendering of a flower at 50, 80 and 90+\" class=\"wp-image-7681 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=800\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 800w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=400\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 400w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 768w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=370\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 370w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=20\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 20w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=185\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 185w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=740\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 740w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=77\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/color-rendering-graphic.png 77w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\"><em>Lights with poor color rendering can make colors appear dull or muddy<\/em><\/figcaption><\/figure>\n\n\n\n<p>While CRI has served as a useful tool for many years, it has several limitations. The eight-color palette used in CRI does not fully represent the vast range of colors present in real life. This becomes apparent when evaluating light sources that excel in rendering the reference colors but perform poorly in accurately rendering other saturated colors. Additionally, CRI does not account for color temperature, making it challenging to compare light sources with different spectral characteristics.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-the-rise-of-tm-30-15-a-more-comprehensive-approach\">The Rise of TM-30-15: A More Comprehensive Approach<\/h2>\n\n\n\n<p>To address the limitations of CRI and provide a fuller evaluation of color rendering, the <a href=\"https:\/\/www.ies.org\/\">Illuminating Engineering Society (IES)<\/a> introduced TM-30-15 in 2015.<sup>[2]<\/sup> The new method offers a more extensive palette of 99 colors. Additionally, TM-30-15 measures color fidelity, gamut and color vector graphics.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png\" alt=\"A graphic showing the color palette used in TM-30-15 versus the 8 and 15 colors of the standard and extended CRI palettes respectively\" class=\"wp-image-7721 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1024\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 1024w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=400\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 400w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 768w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=370\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 370w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=800\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 800w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=20\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 20w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=185\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 185w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=740\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 740w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=91\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2022\/12\/3-color-rendering-scales-1024x538.png 91w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>TM-30-15 measures color rendering accuracy using 99 colors, a significant expansion even over the palette of 15 colors in extended CRI.<\/em><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-color-fidelity-index-rf\"><strong>Color Fidelity Index (Rf)<\/strong><\/h3>\n\n\n\n<p>The <strong>Color Fidelity Index (Rf)<\/strong> is one of the key metrics in TM-30-15. Similar to CRI, it measures the average color rendering performance of a light source. However, unlike CRI, which uses eight pastel colors, Rf in TM-30-15 assesses color fidelity across 99 different colors. A higher Rf score indicates better color accuracy, with a perfect score of 100 representing a light source that renders colors identically to the reference source.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-gamut-index-rg\">Gamut Index (Rg)<\/h3>\n\n\n\n<p>The <strong>Gamut Index (Rg)<\/strong> measures the saturation of colors rendered by a light source compared to a reference source. It provides valuable information about the intensity and vibrancy of colors. A higher Rg score indicates higher color saturation, while lower scores suggest undersaturation. The Gamut Index complements the Color Fidelity Index by capturing the vividness and intensity of colors.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-color-vector-graphics\">Color Vector Graphics<\/h3>\n\n\n\n<p>While Rf and Rg provide numerical scores, <strong>Color Vector Graphics<\/strong> offers a visual representation of color saturation anomalies. This circular vector graph overlays a color space, indicating where the light source may deviate from the reference source in terms of color saturation. By visualizing the specific color areas affected by saturation discrepancies, designers can make more informed decisions about the use of light sources in different applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-the-advancements-of-tm-30-20-a-further-refinement\">The Advancements of TM-30-20: A Further Refinement<\/h2>\n\n\n\n<p>Building upon the foundation of TM-30-15, the IES introduced an updated version, TM-30-20, which offers enhancements and refinements to the evaluation method to provide a more comprehensive and accurate assessment of color rendering.&nbsp;<\/p>\n\n\n\n<p>It uses a wider palette of 99 reference colors, chosen from real-world objects, to evaluate the color fidelity and saturation of a light source. Using the latest research findings and advancements, it offers improved calculations and better alignment with subjective visual outcomes. The <a href=\"https:\/\/www.ies.org\/lda-magazine\/lda-hot-topics\/color-specify-and-conquer\/\">updated standard<\/a> provides specifiers with more accurate and reliable information for selecting light sources that meet their specific design intents and priorities.&nbsp;<\/p>\n\n\n\n<p>TM-30-20 takes into consideration the entire spectrum of light emitted by LEDs, making it a suitable method for evaluating the color rendering capabilities of modern sources.&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"584\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2019\/08\/LEDART6-1024x584.jpg\" alt=\"Improved color rendering accuracy with the TM-30-20 method ensures patrons can view art as intended in galleries\" class=\"wp-image-5374 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1024\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2019\/08\/LEDART6-1024x584.jpg 1024w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=400\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2019\/08\/LEDART6-1024x584.jpg 400w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2019\/08\/LEDART6-1024x584.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>Improving color rendering accuracy in art galleries ensures patrons view art as the artists intended.<\/em><\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-visualizing-color-rendering-with-tm-30-20\">Visualizing Color Rendering with TM-30-20<\/h2>\n\n\n\n<p>To further aid in understanding the color rendering characteristics of a light source, TM-30-20 provides two powerful visual tools: the Color Vector Graph and the Gamut Index.<\/p>\n\n\n\n<p>The <strong>Color Vector Graph<\/strong> is a circular representation superimposed on a color space, revealing any anomalies in color saturation caused by the light source. It shows specific areas of the color spectrum that may be over or undersaturated, providing valuable insights for designers and specifiers. This graph helps identify potential issues and allows for targeted adjustments to achieve the desired color rendering.<\/p>\n\n\n\n<p>The <strong>Gamut Index<\/strong> measures the full range of color saturation under a specific light source compared to natural sunlight. A score of 100 indicates that the colors rendered by the light source are identical to those under natural daylight. Scores below 100 suggest undersaturation, while scores above 100 indicate oversaturation. The Gamut Index accordingly helps designers evaluate the overall color intensity and adjust lighting solutions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-utilizing-tm-30-20-in-lighting-design\">Utilizing TM-30-20 in Lighting Design<\/h2>\n\n\n\n<p>With a solid understanding of TM-30-20 and its key metrics,&nbsp; you can effectively use this method in practical lighting design applications.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1056\" height=\"1124\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,width=1056\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png\" alt=\"A graphic generated using the IES online spectral calculator showing the color rendering accuracy of an LED hybrid bulb. \" class=\"wp-image-8794 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1056\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 1056w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=376\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 376w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=962\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 962w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 768w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=370\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 370w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=800\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 800w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=20\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 20w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=740\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 740w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=45\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/09\/EX90_-LED-Hybrid-Blue-Pump-full.png 45w\" sizes=\"(max-width: 1056px) 100vw, 1056px\" \/><figcaption class=\"wp-element-caption\"><em>Graphic generated using the <a href=\"https:\/\/www.ies.org\/standards\/standards-toolbox\/tm-30-spectral-calculator\/\" target=\"_blank\" rel=\"noreferrer noopener\">IES online spectral calculator<\/a>, in conformance with the ANSI\/IES&nbsp;TM-30-20 standard published by the IES.<\/em><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-specifying-color-rendering-requirements\">1. Specifying Color Rendering Requirements<\/h3>\n\n\n\n<p>TM-30-20 offers a comprehensive set of recommended specification criteria that can be applied in various lighting design scenarios. The specification criteria are based on three design intents:&nbsp;<\/p>\n\n\n\n<ul>\n<li>Preference<\/li>\n\n\n\n<li>Vividness<\/li>\n\n\n\n<li>Fidelity&nbsp;<\/li>\n<\/ul>\n\n\n\n<p>Each design intent has three priority levels, allowing specifiers to fine-tune their requirements based on the specific needs of a project.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-design-intent-preference\">Design Intent: Preference<\/h4>\n\n\n\n<p>The Preference design intent focuses on subjective evaluations of pleasantness, naturalness and acceptability of color rendering. This design intent is particularly relevant in retail, office, hospitality and residential lighting applications. TM-30-20 provides specification criteria for three priority levels within the Preference design intent, ranging from strict requirements to more flexible ranges.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-design-intent-vividness\">Design Intent: Vividness<\/h4>\n\n\n\n<p>The Vividness design intent centers around subjective evaluations of color vividness, saturation and vibrancy. This design intent is often crucial in entertainment, display and retail applications. TM-30-20 offers specification criteria for three priority levels within the Vividness design intent, allowing specifiers to select light sources that enhance color vividness while considering potential hue distortions.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-design-intent-fidelity\">Design Intent: Fidelity<\/h4>\n\n\n\n<p>The Fidelity design intent focuses on achieving a high match between a test light source and its reference. This design intent is essential in applications like healthcare and color matching, where color accuracy is of utmost importance. TM-30-20 provides specification criteria for three priority levels within the Fidelity design intent, ensuring consistency and minimizing color shifts.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-understanding-priority-levels\">2. Understanding Priority Levels<\/h3>\n\n\n\n<p>TM-30-20 introduces priority levels within each design intent to provide further customization and flexibility. These priority levels allow designers to fine-tune their specifications based on the specific requirements of a project.<\/p>\n\n\n\n<p>Priority Level 1 has the strictest requirements, ensuring the highest level of color accuracy or saturation. However, it may limit the available selection of light sources. Priority Level 3, on the other hand, allows for variability in color rendering performance but still meets the general intent. Designers must carefully evaluate the project&#8217;s needs and select the appropriate priority level.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-evaluating-light-sources\">3. Evaluating Light Sources<\/h3>\n\n\n\n<p>When evaluating light sources using TM-30-20, it is crucial to consider both the Rf and Rg metrics, along with the Color Vector Graph and Gamut Index. These metrics provide a comprehensive understanding of color rendering performance and allow for informed decision-making.<\/p>\n\n\n\n<p>By analyzing the Color Vector Graph, designers can identify any specific color areas that may require adjustment or improvement. The Gamut Index helps assess the overall color saturation and intensity, ensuring that the lighting solution aligns with the desired visual impact.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"940\" height=\"600\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2017\/04\/Adjustable-LED-Receseed-Square-Recessed.jpg\" alt=\"\" class=\"wp-image-3554 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=940\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2017\/04\/Adjustable-LED-Receseed-Square-Recessed.jpg 940w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=400\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2017\/04\/Adjustable-LED-Receseed-Square-Recessed.jpg 400w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2017\/04\/Adjustable-LED-Receseed-Square-Recessed.jpg 768w\" sizes=\"(max-width: 940px) 100vw, 940px\" \/><figcaption class=\"wp-element-caption\"><em>Accurate color rendering in retail stores allows vibrant products to stand out and enhances the customer experience.  <\/em><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-4-collaborating-with-manufacturers\">4. Collaborating with Manufacturers<\/h3>\n\n\n\n<p>As TM-30-20 gains wider adoption, it is essential for designers to collaborate with lighting manufacturers to ensure the availability of light sources that meet the specified color rendering requirements. Manufacturers can leverage the insights provided by TM-30-20 to develop and market products that align with different design intents and priority levels.<\/p>\n\n\n\n<p>By closely working with manufacturers, designers can access a wider range of lighting options that deliver the desired color rendering qualities and enhance the overall lighting design.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-conclusion\">Conclusion<\/h2>\n\n\n\n<p>With the introduction of TM-30-20, the lighting industry has made progress in color rendering evaluation by providing a more comprehensive and accurate method for evaluating color fidelity and saturation. With its key metrics, visual tools, and customizable design intents, TM-30-20 offers designers the ability to tailor lighting solutions to specific project requirements. By embracing this revolutionary approach, designers can elevate the visual experience, improve aesthetics and create lighting environments that showcase the beauty of color.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-citations\">Citations<\/h4>\n\n\n\n[1] <a href=\"https:\/\/www.lrc.rpi.edu\/programs\/solidstate\/assist\/pdf\/AR-ColorGuideforRetailLighting-March2010.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Guide to Light and Color in Retail Merchandising<\/a>. (2010). <em>Assist Recommends&#8230;<\/em>, <em>8<\/em>(1), 4\u201313. <\/p>\n\n\n\n[2] Illuminating Engineering Society. (2020). (tech.). <em>Technical Memorandum: IES Method for Evaluating Light Source Color Rendition<\/em> (pp. 1\u201358). New York, NY.&nbsp;<\/p>\n\n\n\n[3] Livingston, J., Royer, M., &amp; Esposito, T. (2022, April 4). <em><a href=\"https:\/\/www.ies.org\/research\/fires\/using-tm-30-to-improve-your-lighting-design\/?_ga=2.160519677.1979189151.1693672220-1208566590.1691722488\" target=\"_blank\" rel=\"noreferrer noopener\">Using TM-30 to improve your lighting design<\/a><\/em>. Illuminating Engineering Society. &nbsp;<\/p>\n\n\n\n[4] Rea, M. S., &amp; Freyssinier, J. P. (2010). Color rendering: Beyond Pride and Prejudice. <em><a href=\"https:\/\/doi.org\/10.1002\/col.20562\" target=\"_blank\" rel=\"noreferrer noopener\">Color Research &amp; Application<\/a><\/em>, <em>35<\/em>(6), 401\u2013409. &nbsp;<\/p>\n\n\n\n[5] Royer, M., &amp; Houser, K. (2015a). <em>Text-alternative version: <\/em><a href=\"https:\/\/www.energy.gov\/eere\/ssl\/text-alternative-version-understanding-and-applying-tm-30-15\" target=\"_blank\" rel=\"noreferrer noopener\"><em>Understanding and applying TM-30-15<\/em><\/a>. Energy.gov. &nbsp;<\/p>\n\n\n\n<p>Royer, M., &amp; Houser, K. (2015). <em>Understanding and applying TM-30-15 &#8211; Department of Energy<\/em>. <a href=\"https:\/\/www.energy.gov\/eere\/ssl\/downloads\/presentation-slides-understanding-and-applying-tm-30-15\" target=\"_blank\" rel=\"noreferrer noopener\">Understanding and Applying TM-30-15 Webinar<\/a>. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>The TM-30-20 method improves accuracy in evaluating the color rendering accuracy of light sources, such as LEDs. Discover how it works. <\/p>\n","protected":false},"author":104,"featured_media":8607,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","footnotes":""},"categories":[349],"tags":[792,770],"thb-sponsors":[],"ppma_author":[801,773],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v20.13) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>TM-30-20 Reinvents Color Rendering in Lighting Design<\/title>\n<meta name=\"description\" content=\"This introduction to the TM-30-20 method explains how this new system allows designers to ensure accurate color rendering in lighting design.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reimagining Color Rendering in Lighting Design: An Introduction to TM-30-20\" \/>\n<meta property=\"og:description\" content=\"This introduction to the TM-30-20 method explains how this new system allows designers to ensure accurate color rendering in lighting design.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/\" \/>\n<meta property=\"og:site_name\" content=\"Insights\" \/>\n<meta property=\"article:published_time\" content=\"2023-09-25T17:29:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-23T20:42:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=2560\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/05\/LinearSuspensionLighting-scaled.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Lindsay Stevens, David Hakimi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Lindsay Stevens\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"TM-30-20 Reinvents Color Rendering in Lighting Design","description":"This introduction to the TM-30-20 method explains how this new system allows designers to ensure accurate color rendering in lighting design.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/","og_locale":"en_US","og_type":"article","og_title":"Reimagining Color Rendering in Lighting Design: An Introduction to TM-30-20","og_description":"This introduction to the TM-30-20 method explains how this new system allows designers to ensure accurate color rendering in lighting design.","og_url":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/","og_site_name":"Insights","article_published_time":"2023-09-25T17:29:22+00:00","article_modified_time":"2024-02-23T20:42:03+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=2560\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/05\/LinearSuspensionLighting-scaled.jpeg","type":"image\/jpeg"}],"author":"Lindsay Stevens, David Hakimi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Lindsay Stevens","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/","url":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/","name":"TM-30-20 Reinvents Color Rendering in Lighting Design","isPartOf":{"@id":"https:\/\/www.alconlighting.com\/blog\/#website"},"datePublished":"2023-09-25T17:29:22+00:00","dateModified":"2024-02-23T20:42:03+00:00","author":{"@id":"https:\/\/www.alconlighting.com\/blog\/#\/schema\/person\/8fe43f4446f7f5feb910df5234a51e6e"},"description":"This introduction to the TM-30-20 method explains how this new system allows designers to ensure accurate color rendering in lighting design.","breadcrumb":{"@id":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/"]}],"accessibilityFeature":["tableOfContents"]},{"@type":"BreadcrumbList","@id":"https:\/\/www.alconlighting.com\/blog\/learning-lab\/tm-30-20-color-rendering-lighting-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.alconlighting.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Reimagining Color Rendering in Lighting Design: An Introduction to TM-30-20"}]},{"@type":"WebSite","@id":"https:\/\/www.alconlighting.com\/blog\/#website","url":"https:\/\/www.alconlighting.com\/blog\/","name":"Insights","description":"The Intersection of Lighting, Efficiency and Architecture","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.alconlighting.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.alconlighting.com\/blog\/#\/schema\/person\/8fe43f4446f7f5feb910df5234a51e6e","name":"Lindsay Stevens","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.alconlighting.com\/blog\/#\/schema\/person\/image\/dc136e5866d89fce530aa1a59b9cd99a","url":"https:\/\/secure.gravatar.com\/avatar\/4781c40c2837c1e38a0228e2f60bf894?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4781c40c2837c1e38a0228e2f60bf894?s=96&d=mm&r=g","caption":"Lindsay Stevens"},"description":"Lindsay Alayne Stevens is a multidisciplinary designer, artist and writer. She holds an MFA in Theater Design (Lighting) from UCSD ('21) and BFAs with High Honors from Marlboro College in Theater, Photography, and Writing ('17). She works as a freelance lighting designer and teaches lighting at the university level.","sameAs":["https:\/\/www.linkedin.com\/in\/lindsay-alayne-stevens\/"],"url":"https:\/\/www.alconlighting.com\/blog\/author\/lindsay-stevens\/"}]}},"modified_by":"David Hakimi","authors":[{"term_id":801,"user_id":104,"is_guest":0,"slug":"lindsay-stevens","display_name":"Lindsay Stevens","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/4781c40c2837c1e38a0228e2f60bf894?s=96&d=mm&r=g","first_name":"Lindsay","last_name":"Stevens","user_url":"","description":"Lindsay Alayne Stevens is a multidisciplinary designer, artist and writer. She holds an MFA in Theater Design (Lighting) from UCSD ('21) and BFAs with High Honors from Marlboro College in Theater, Photography, and Writing ('17). She works as a freelance lighting designer and teaches lighting at the university level."},{"term_id":773,"user_id":1,"is_guest":0,"slug":"admin","display_name":"David Hakimi","avatar_url":{"url":"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=90\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/08\/David-Hakimi-Alcon-Lighting-Inc.-1-1-90x90.png","url2x":"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=180\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2023\/08\/David-Hakimi-Alcon-Lighting-Inc.-1-1-180x180.png"},"first_name":"David","last_name":"Hakimi","user_url":"https:\/\/www.alconlighting.com","description":"Alcon Lighting creative director and co-founder David Hakimi works to improve lighting through research, development and education. David strives for efficiency in lighting, affording architects, lighting designers and engineers the ability to maximize LED lighting design and application. \r\n\r\nDavid is a graduate of the University of California, Los Angeles, where he received a Bachelors in history. David also studied lighting design at IES in Los Angeles. He traces his and Alcon Lighting\u2019s commitment to innovation, accountability, quality and value to lessons learned from his father, Mike Hakimi, a lighting craftsman, salesman and consultant in Southern California for more than four decades.\r\n\r\nToday\u2019s lighting for commercial use requires a deep, complete understanding of smart lighting systems and controls. David takes pride in his lighting, energy controls and design knowledge. He is driven by the desire to share his insights into lighting specification and application. This quest to share his knowledge was the impetus for David to create Insights, Alcon Lighting\u2019s blog and resource center for helping the reader understand lighting and its application to space."}],"_links":{"self":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts\/8766"}],"collection":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/users\/104"}],"replies":[{"embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/comments?post=8766"}],"version-history":[{"count":9,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts\/8766\/revisions"}],"predecessor-version":[{"id":8990,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts\/8766\/revisions\/8990"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/media\/8607"}],"wp:attachment":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/media?parent=8766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/categories?post=8766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/tags?post=8766"},{"taxonomy":"thb-sponsors","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/thb-sponsors?post=8766"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/ppma_author?post=8766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}