{"id":10303,"date":"2026-08-07T11:55:33","date_gmt":"2026-08-07T18:55:33","guid":{"rendered":"https:\/\/www.alconlighting.com\/blog\/?p=10303"},"modified":"2026-08-07T11:55:35","modified_gmt":"2026-08-07T18:55:35","slug":"2026-lighting-code-updates","status":"publish","type":"post","link":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/","title":{"rendered":"2026 Lighting Code Updates: California Title 24 and ASHRAE 90.1"},"content":{"rendered":"\n<p>Complying with government regulations and other building construction codes requires staying informed of the regular updates. Lighting regulations mandate fixtures, controls and energy standards throughout the lighting industry. Energy regulations aim to conserve energy, improve efficiency and safety for new construction and remodel, commercial and residential developments.<\/p>\n\n\n\n<p>The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) maintains a national U.S. standard, which many states use to enact energy policy. ASHRAE, Illuminating Engineering Society (IES) and American National Standards Institute (ANSI) collaborate to publish certain standard updates. For building energy efficiency, <strong>California&#8217;s Title 24, Part 6<\/strong> is published and maintained by the <strong>California Energy Commission (CEC)<\/strong>. The CEC develops the standards, updates them on a three-year cycle, and adopts them into California&#8217;s Building Energy Efficiency Standards. The current 2025 standards became effective on <strong>January 1, 2026<\/strong>. Because California is such a large construction and lighting market, manufacturers often design products to satisfy Title 24&#8217;s stringent requirements. Features that were once unique to California\u2014such as advanced occupancy sensors, daylight harvesting, high-end dimming controls, and demand-responsive lighting controls\u2014have gradually become common across North America.<\/p>\n\n\n\n<div class=\"wp-block-yoast-seo-table-of-contents yoast-table-of-contents\"><h2>Table of contents<\/h2><ul><li><a href=\"#h-ashrae-updates\" data-level=\"2\">ASHRAE Updates<\/a><\/li><li><a href=\"#h-additional-restrictions-in-california-s-title-24\" data-level=\"2\">Additional Restrictions in California\u2019s Title 24<\/a><ul><li><a href=\"#h-notable-changes\" data-level=\"3\">Notable changes<\/a><\/li><li><a href=\"#h-controls\" data-level=\"3\">Controls<\/a><\/li><\/ul><\/li><li><a href=\"#h-conclusion\" data-level=\"2\">Conclusion<\/a><\/li><\/ul><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-ashrae-updates\">ASHRAE Updates<\/h2>\n\n\n\n<p>ASHRAE included a series of addenda to the existing 90.1-2022 standard. Accordingly, designers and engineers ought to review ASHRAE\u2019s Light Power Density (LPD) updates. Previous LPD Table 9.5.1.2-1 is now split into tables in sections 9.4 and 9.5.2 to separately address power and controls. Updates to Light Loss Depreciation (LLD) and luminaire efficacy (two percent increase) result in a 6.5 percent average reduction in space-by-space LPD values.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2500\" height=\"1667\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=2500\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg\" alt=\"Pendant-mounted LED high bay lights illuminate aircraft and maintenance areas inside a large commercial hangar.\" class=\"wp-image-10305 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=2500\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 2500w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=400\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 400w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1024\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 1024w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 768w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1536\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 1536w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=2048\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 2048w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=370\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 370w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=800\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 800w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=20\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 20w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=740\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 740w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1600\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 1600w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=72\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/Hangar-D_High-Bay-Lighting.jpg 72w\" sizes=\"(max-width: 2500px) 100vw, 2500px\" \/><figcaption class=\"wp-element-caption\"><em><a href=\"https:\/\/www.alconlighting.com\/commercial\/highbay-lighting.html\">High-bay lighting<\/a> for large production facilities, warehouses and in this case, airplane hangars, require careful evaluation of lighting power density, luminaire efficacy and controls to meet project-specific energy-code requirements.<\/em><\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In section 9.4, apart from various updates to technical errors and terminology, there are also changes to controls requirements. For certain spaces where use is not common, local controls and multilevel control requirements have been removed. Automatic reduction control is also added in space types to restrict lighting energy. New lighting controls now apply to some healthcare facilities with an aim to reduce lighting to accommodate human circadian rhythm.&nbsp;<\/p>\n\n\n\n<p>Controls for office spaces larger than 300 square feet are further defined. Occupancy sensor time delay is reduced from 20 to 15 minutes, mandating a two to five percent energy reduction. Newly imposed provisions are intended to close loopholes.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1024\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg\" alt=\"Suspended linear pendants, track lights and cove lighting illuminate an open office with daylight from floor-to-ceiling windows.\" class=\"wp-image-10312 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=1024\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 1024w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=400\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 400w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=768\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 768w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=370\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 370w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=800\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 800w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=20\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 20w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=740\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 740w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=64\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2019_12_16_GraSpe06_A-1024x768.jpg 64w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em><a href=\"https:\/\/www.alconlighting.com\/shop-by-application\/led-office-lighting.html\">Open office lightin<\/a><a href=\"https:\/\/www.alconlighting.com\/shop-by-application\/led-office-lighting.html\" target=\"_blank\" rel=\"noreferrer noopener\">g<\/a> may require coordinated occupancy sensing, automatic lighting reduction and separate control zones based on space configuration and available daylight.<\/em><\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>ASHRAE added new controls to exit-related lights, reducing building exit access lighting power allowance from 0.02 W\/ft<sup>2<\/sup> to 0.01 W\/ft<sup>2<\/sup> across the lighted floor area.<\/p>\n\n\n\n<p>Energy controls for daylight are also stricter. Wattage for automatic daylight response controls for sidelighting areas for conditions where there is not much power went down. Combined primary and secondary sidelight daylight area wattage is now standardized to 75 watts each predicated on controllability and use of LED multilevel lighting. The minimum value of lighting power by automatic daylight responsive control system is halved from 20 percent to 10 percent power (Section 9.4.1.1).<\/p>\n\n\n\n<p>ASHRAE 90.1 is a model energy standard, so its requirements apply only when the relevant edition has been adopted by the governing jurisdiction. Consult state and local regulations for your project, which may be more or less strict.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-additional-restrictions-in-california-s-title-24\">Additional Restrictions in California\u2019s Title 24<\/h2>\n\n\n\n<p>In 2026, Title 24 adds new restrictions on lighting power, fixtures and controls (including daylighting). Refer to building energy efficiency controls on the official Title 24 government regulation <a href=\"https:\/\/www.energy.ca.gov\/sites\/default\/files\/2026-07\/CEC-400-2025-010-F.pdf\">site<\/a>. Use the link to review California lighting regulation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-notable-changes\">Notable changes<\/h3>\n\n\n\n<ul>\n<li>Changes to indoor Lighting Power Allowance (LPA) and Power Adjustment Factor (PAF), section 140.6.\n<ul>\n<li>The Complete Building Method (on page 338) and the Area Category Method (on page 341) still determine the state\u2019s Lighting Power Allowance. Review Area Category Method for updates to individual space type power allowance. Additional Lighting Power Allowances are available for certain individual space types and may be noted on the right Table 140.6-C column.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>The state eliminates the Tailor method as compliance method. Wattage flexibility is now offered in additional allowances to Area Category Method.<\/li>\n\n\n\n<li>All government-allowed illuminated sign lighting must now be LED or neon fixtures.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-controls\">Controls<\/h3>\n\n\n\n<ul>\n<li>Power Adjustment factors for daylighting and occupancy sensor controls are found on page 333 Table 140.6-A.&nbsp;<\/li>\n\n\n\n<li>Manual Area control section 130.1(a)2 (on page 260) are changed. Manual controls must now be located in the same space or visible from space.<\/li>\n\n\n\n<li>Table 130.1A has been eliminated. Multi-level lighting must have continuous dimming to 10 percent or lower. Legacy HID or induction light sources are exempt from full continuous dimming, but are required to provide at least one control step between 30 and 70 percent of full rated power.<\/li>\n\n\n\n<li>Primary, secondary and skylit indoor daylit zone wattage has been changed from 120 to 75 watts. (130.1d)<\/li>\n\n\n\n<li>If a primary daylit zone is not required and secondary daylit zone is less than 85 watts, daylighting controls for secondary zones are now exempted (130.1d).<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"683\" height=\"1024\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=683\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2024_10_14_PWbowie09_A-683x1024.jpg\" alt=\"Integrated linear LED lighting supplements natural light entering a modern commercial interior through expansive glazing and overhead openings.\" class=\"wp-image-10313 lazyload\" data-sizes=\"auto\" data-srcset=\"https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=683\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2024_10_14_PWbowie09_A-683x1024.jpg 683w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=267\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2024_10_14_PWbowie09_A-683x1024.jpg 267w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=370\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2024_10_14_PWbowie09_A-683x1024.jpg 370w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=20\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2024_10_14_PWbowie09_A-683x1024.jpg 20w, https:\/\/www.alconlighting.com\/cdn-cgi\/image\/fit=contain,format=webp,quality=80,width=32\/https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/2024_10_14_PWbowie09_A-683x1024.jpg 32w\" sizes=\"(max-width: 683px) 100vw, 683px\" \/><figcaption class=\"wp-element-caption\"><em><a href=\"https:\/\/www.alconlighting.com\/led\/continuum-linear-lighting\/l\/commercial-features:daylightsensor.html\">Daylight-responsive controls<\/a> adjust electric lighting based on available natural light, helping projects reduce lighting energy while maintaining appropriate illumination levels.<\/em><\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-conclusion\">Conclusion<\/h2>\n\n\n\n<p>These updates to ASHRAE\/IES\/ANSI and Title 24 include notable changes. Updates made in 2025 are in effect for 2026 and <em>must<\/em> be followed for government energy compliance. Individual space type requirements, including additional allowances, should be reviewed for specific power allowance requirements. Minimizing energy usage through lighting wattage and controls design is mandated to save energy and lower the carbon footprint while providing cost savings. These changes are intended to improve lighting efficiency through controls while supporting a better experience within these spaces.<\/p>\n\n\n\n<p><strong>Sources:<\/strong><\/p>\n\n\n\n<p>California Energy Commission. <a href=\"https:\/\/www.energy.ca.gov\/programs-and-topics\/programs\/building-energy-efficiency-standards\/2025-building-energy-efficiency\" target=\"_blank\" rel=\"noreferrer noopener\">2025 Building Energy Efficiency Standards<\/a> [<a href=\"https:\/\/www.energy.ca.gov\/sites\/default\/files\/2026-07\/CEC-400-2025-010-F.pdf\">PDF<\/a>].<\/p>\n\n\n\n<p>ASHRAE\/IES\/ANSI. <a href=\"https:\/\/www.ashrae.org\/file%20library\/technical%20resources\/standards%20and%20guidelines\/standards%20addenda\/90_1_2022_s_20240723.pdf\">Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings<\/a>.<\/p>\n\n\n\n<p>ASHRAE\/IES\/ANSI. <a href=\"https:\/\/www.ashrae.org\/file%20library\/technical%20resources\/standards%20and%20guidelines\/standards%20addenda\/90_1_2022_bd_20250509.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, Addenda 1<\/a>. <\/p>\n\n\n\n<p>ASHRAE\/IES\/ANSI. <a href=\"https:\/\/www.ashrae.org\/file%20library\/technical%20resources\/standards%20and%20guidelines\/standards%20addenda\/90_1_2022_be_20250530.pdf\">Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, Addenda 2<\/a>. <\/p>\n\n\n\n<p>ASHRAE\/IES\/ANSI. <a href=\"https:\/\/www.ashrae.org\/file%20library\/technical%20resources\/standards%20and%20guidelines\/standards%20addenda\/90_1_2022_co_20250829.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, Addenda 3<\/a>. <\/p>\n\n\n\n<p><br \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>California\u2019s 2025 Energy Code took effect January 1, 2026, while ASHRAE 90.1 continues to tighten lighting power and control requirements. Discover what&#8217;s changed in commercial lighting requirements and what project teams should verify before specifying a system.<\/p>\n","protected":false},"author":105,"featured_media":10304,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","footnotes":""},"categories":[312],"tags":[],"thb-sponsors":[],"ppma_author":[802],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.13 (Yoast SEO v20.13) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>2026 Lighting Code Updates: Title 24 and ASHRAE 90.1 | Insights<\/title>\n<meta name=\"description\" content=\"Review 2026 California Title 24 and ASHRAE 90.1 lighting updates covering power allowances, continuous dimming, controls and daylighting.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"2026 Lighting Code Updates: California Title 24 and ASHRAE 90.1\" \/>\n<meta property=\"og:description\" content=\"Review 2026 California Title 24 and ASHRAE 90.1 lighting updates covering power allowances, continuous dimming, controls and daylighting.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/\" \/>\n<meta property=\"og:site_name\" content=\"Insights\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-07T18:55:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-07T18:55:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/TAMU-Wellness-Center-Gym-High-Bay-1024x683.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Garrett Rock\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Garrett Rock\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"2026 Lighting Code Updates: Title 24 and ASHRAE 90.1 | Insights","description":"Review 2026 California Title 24 and ASHRAE 90.1 lighting updates covering power allowances, continuous dimming, controls and daylighting.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/","og_locale":"en_US","og_type":"article","og_title":"2026 Lighting Code Updates: California Title 24 and ASHRAE 90.1","og_description":"Review 2026 California Title 24 and ASHRAE 90.1 lighting updates covering power allowances, continuous dimming, controls and daylighting.","og_url":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/","og_site_name":"Insights","article_published_time":"2026-08-07T18:55:33+00:00","article_modified_time":"2026-08-07T18:55:35+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/www.alconlighting.com\/blog\/wp-content\/uploads\/2026\/08\/TAMU-Wellness-Center-Gym-High-Bay-1024x683.jpg","type":"image\/jpeg"}],"author":"Garrett Rock","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Garrett Rock","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/","url":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/","name":"2026 Lighting Code Updates: Title 24 and ASHRAE 90.1 | Insights","isPartOf":{"@id":"https:\/\/www.alconlighting.com\/blog\/#website"},"datePublished":"2026-08-07T18:55:33+00:00","dateModified":"2026-08-07T18:55:35+00:00","author":{"@id":"https:\/\/www.alconlighting.com\/blog\/#\/schema\/person\/f25949e39582f490b85487d1d7aef77e"},"description":"Review 2026 California Title 24 and ASHRAE 90.1 lighting updates covering power allowances, continuous dimming, controls and daylighting.","breadcrumb":{"@id":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/"]}],"accessibilityFeature":["tableOfContents"]},{"@type":"BreadcrumbList","@id":"https:\/\/www.alconlighting.com\/blog\/lighting-news\/2026-lighting-code-updates\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.alconlighting.com\/blog\/"},{"@type":"ListItem","position":2,"name":"2026 Lighting Code Updates: California Title 24 and ASHRAE 90.1"}]},{"@type":"WebSite","@id":"https:\/\/www.alconlighting.com\/blog\/#website","url":"https:\/\/www.alconlighting.com\/blog\/","name":"Insights","description":"The Intersection of Lighting, Efficiency and Architecture","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.alconlighting.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.alconlighting.com\/blog\/#\/schema\/person\/f25949e39582f490b85487d1d7aef77e","name":"Garrett Rock","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.alconlighting.com\/blog\/#\/schema\/person\/image\/de330bd46ba5e963e6e4d7e63c1a51c5","url":"https:\/\/secure.gravatar.com\/avatar\/078a704a6ad65f8193aba1f19bfe70ad?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/078a704a6ad65f8193aba1f19bfe70ad?s=96&d=mm&r=g","caption":"Garrett Rock"},"description":"Garrett Rock is a seasoned lighting designer based in San Francisco, California. He earned his bachelor's degree in Interior Design from the University of California, Davis, and a Master's in Architecture from the California College of the Arts. Throughout his career, Garrett has contributed to firms such as Architecture &amp; Light, Banks Landl Lighting Design, Geddes Ulinskas Architects and WSP. He currently serves as a lighting design consultant for Alcon Lighting and a technical writer for Insights, where he specializes in keeping readers current on energy regulations and in human-centric lighting guides for healthcare settings, retail and other commercial applications.","sameAs":["https:\/\/www.linkedin.com\/in\/garrett-rock-728a4321\/"],"url":"https:\/\/www.alconlighting.com\/blog\/author\/garrett-rock\/"}]}},"modified_by":"David Hakimi","authors":[{"term_id":802,"user_id":105,"is_guest":0,"slug":"garrett-rock","display_name":"Garrett Rock","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/078a704a6ad65f8193aba1f19bfe70ad?s=96&d=mm&r=g","first_name":"Garrett","last_name":"Rock","user_url":"","description":"Garrett Rock is a seasoned lighting designer based in San Francisco, California. He earned his bachelor's degree in Interior Design from the University of California, Davis, and a Master's in Architecture from the California College of the Arts. Throughout his career, Garrett has contributed to firms such as Architecture &amp; Light, Banks Landl Lighting Design, Geddes Ulinskas Architects and WSP. He currently serves as a lighting design consultant for Alcon Lighting and a technical writer for Insights, where he specializes in keeping readers current on energy regulations and in human-centric lighting guides for healthcare settings, retail and other commercial applications."}],"_links":{"self":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts\/10303"}],"collection":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/users\/105"}],"replies":[{"embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/comments?post=10303"}],"version-history":[{"count":7,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts\/10303\/revisions"}],"predecessor-version":[{"id":10321,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/posts\/10303\/revisions\/10321"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/media\/10304"}],"wp:attachment":[{"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/media?parent=10303"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/categories?post=10303"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/tags?post=10303"},{"taxonomy":"thb-sponsors","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/thb-sponsors?post=10303"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.alconlighting.com\/blog\/wp-json\/wp\/v2\/ppma_author?post=10303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}